1.5hp 120V V-System 1500 35 Gal. Freestanding HEPA-GFM Cyclone Dust Collector

$3,499.00
  • Industrial 120V U.S. made fan motor provides ample CFM for any single tool with a 4"-6" dust port. Includes RF remote control starter.
  • High efficiency cyclone separator (removes over 99% of fine wood dust) with smooth, compound molded surface.
  • Ultra-quiet noise level with included sound filters - only 72 dBA at 10 feet.
  • 35 gallon dust bin with quick-release lid and automatic fill level indicator.
  • HEPA-grade media filter with non-stick membrane for easy cleaning.
  • Durable, lightweight construction allows for quick and easy installation.

Quiet, Compact, and Powerful - Ideal for Small Personal Workshops!

This system is designed to collect dust from a single tool at a time (more if blast gates are used) and is ideal for use in small 1-man shops operating tools such as lathes, planers, radial/miter saws, and more!

The V-System's molded static dissipative resin construction speeds up and simplifies system assembly, maximizes airflow performance, and significantly reduces noise levels.

Learn how the V-System helped Kawneer North America improve their production workflows. Read the case study.

Included Features & Components:

  • Industrial 1.5HP 120V U.S. Made Motor (Upgrade to 230V power)
  • Magnetic Starter w/ Overload Protector
  • Wireless RF Remote Control Keyfob
  • High-Efficiency Molded Cyclone Separator
  • HEPA-Grade Filter Media
  • Stacking Sound Filter & Drop-in Silencer
  • Compact Steel Angle Frame Stand
  • 35-Gallon Reinforced Steel Dust Bin
  • Dust Sentryâ„¢ Bin Fill Level Indicator
  • 1 Year Limited Warranty
  • cETLus Certified and NFPA Compliance Ready

V-System Product Family Fan Performance Curve
Oneida Air Systems uses Actual CFM Ratings that reflect real-world airflow performance.

Continuously High Airflow Performance

Your dust collector should perform at peak efficiency at all times to ensure the health, safety, and quality of your work. That's why Oneida Air Systems uses only the highest quality motors with our dust collection systems. Far superior than the cheap, foreign imported motors used by other manufacturers, our industrial-grade motors are built to last a lifetime.

  • High-efficiency, U.S. made fan motor.
  • Delivers ample airflow for a large, single machine with 4" to 6" dust ports.
  • Industrial brushless motor designed for continuous duty.
  • Radio frequency (RF) remote control works through walls up to 100 feet away.
  • System's inlet and outlet rotate independently at 45 degree increments to suit your shop's needs.
  • Low pitch noise level provides ideal operator comfort.
Closeup of V-System cyclone inlet

Streamlined Integrated Cyclone Separator

The V-System features a high-efficiency cyclone separator that removes over 99% of fine wood dusts from the airstream and contains it safely below the cyclone - preventing dust from clogging the filter.

  • Virtually eliminates filter clogging and suction loss to provide continuous suction performance.
  • Significantly extends the lifespan of the filter and reduces downtime needed for cleaning.
  • Smooth, molded design reduces air turbulence to improve airflow performance and lower overall noise output.
  • 7" dia. neutral-vane inlet for use with common 6" ductwork layouts (reducers available).
  • Patented "V-Shape" cyclone design minimizes the system's overall height while maintaining airflow and separation efficiency.
V-System Filter and Plenum

High Quality & Serviceable Filtration

The V-System system uses HEPA-grade media cartridge filters that are specifically designed for dust collection applications - providing unbeatable airflow and filtration performance. Read more about The Advantages of Oneida Air Systems' HEPA-Grade Media Filters »

  • We fully stand by the quality and performance of our filters; each filter is sent to an accredited independent testing lab. Contact us for more information and documentation.
  • Stacking Sound Filter and internal silencer reduce overall noise output of the system by up to 6 dBA. The V-1500 is one of the industry's quietest dust collection systems!
  • Patented Flame Guardâ„¢ safety mesh rapidly dissipate any heat generated by a deflagration within your filter, helping to comply with future planned NFPA fire safety codes.
  • Fine dust pan captures residual dust that falls off the inside of the filter. Can be removed easily for cleaning after reverse blowing compressed air into the pleats.
V-System Stand

Compact, Configurable Design

This unit is equipped with a Freestanding Leg Kit and has been built specifically to fit underneath standard 8 foot ceilings; perfect for garage or basement shops!

Please Note: The Leg Extension Kit is required if you wish to use a drum dolly with this system. See product documentation for more details and dimensions.

Opening the Dust Bin
Release the dust bin's locking lever clamp and lift off the lid.
Removing the Full Dust Bin
Pull the dust bin out from under the cyclone.
Reinstalling the Empty Dust Bin
Empty the dust bin out and reattach to the cyclone when ready.

Convenient Pull-Out Dust Bin

Our dust collection bins are made simple for a reason: convenience. With no assembly required, these robust, steel drums are quick and easy to use when disposing of dust and debris. The dust collector comes equipped with a 35 gallon steel drum - best for holding a large amount of dust and debris without being overwhelming when full. Drum dollies and bag holding sleeves are also available to make emptying the drum cleaner and more efficient.

More Information
Horsepower 1-1/2 hp
Motor Type U.S. TEFC Motor
Motor Service Factor 1.15
Voltage 110-120V
Recommended Breaker Size 20A
Amperage (Typical) 8A
Phase Option Single-Phase (Pre-Wired)
Frequency 60Hz
Power Connector Type NEMA 5-15
NEMA 5-15 Plug Type, 125V/15A
Power Cord Length 10 feet
Impeller Type Single-piece, backward inclined, non-sparking/non-ferrous
Impeller Size 13" Dia.
Real CFM Rating 1,130 Actual CFM at 2.7" WC
Free Fan CFM Rating 1,750 CFM
Maximum Suction 8.7" WC
Max. Open Blast Gates 1 Gate
Noise Level 68 dBA @ 10 ft
Cyclonic Separation Efficiency Removes over 99% of fine wood dusts
Filter Type HEPA Grade ePTFE Media
Filtration Efficiency E12 Minimum Efficiency Rating
Total Filtration Area 95 sq ft
Waste Capacity 35 Gallons
Remote Control Included
Remote Control Part # See Item #AMR000000 for additional or replacement keyfobs.
Primary Build Materials Static Dissipative Polyethylene
Welding N/A
Static Resistance Rating Static Dissipative
Color Black
Inlet Size 7" OD
Outlet Size Square ID: 7-3/8"(W) x 6-3/8"(H)
Discharge Size 7" Dia.
Width 47"
Depth 30"
Height 87"
Height to Center of Inlet 63"
Contents Blower Motor Assembly, Magnetic Starter, Fan Housing, Filter Plenum, Stacking Sound Filter, Internal Silencer, FlameGuard Cartridge Filter, Freestanding Leg Kit, Cyclone Separator, Steel Dust Bin, Bin Level Indicator, Remote Control, Hardware
Manufacturer Oneida Air Systems
Manufacturer Statement Made in USA
Warranty Information N/A
Certifications NFPA Compliance Ready (See Reference Guide).
cETLus certified to both U.S. and Canadian product safety standards by an NRTL.
Conforms to UL-1017 and Can/CSA-C22.2 No. 243 standards.
Proposition 65 WARNING: This product may expose you to chemicals, including Carbon Black (airborne, unbound particles of respirable size), which is known to the State of California to cause cancer or birth defects or reproductive harm.
How often should I clean the dust collector's cartridge filter?
This can vary widely depending on how often your dust collector is used and what kind of dusts it's exposed to but you should typically clean it only once you've noticed a considerable drop in suction performance. In our experience this can be around once per year, but with heavy amounts of sanding it could be as often as once per month. A meter such as our Filter Efficiency Gauge can also be used to monitor pressure buildup and inform you when the filter needs to be cleaned.
What is the floor space required for the V-1500 w/ 35 gallon drum?
On the floor, the V-System's stand is a 30" x 30" square. How wide the overall system is depends on the orientation of your filter plenum. If the plenum is oriented ninety degrees clockwise from the system's inlet, then the overall width would be 47". Please refer to the owner's manual for more detailed dimensions.
Can the V-System be used with a smaller dust bin to lower the total height?
With the stand, the V-System's overall height cannot be lower than 87" (for 1.5HP) or 88" (for 3HP). Oneida Air Systems does offer wall-mounting brackets for the V-System. This would allow you to mount the V-System dust collector at a lower height for use with smaller containers. Please note that you may have to empty the smaller drum much more frequently depending on your workflow.
What do I need to know about NFPA regulations?
Fire protection regulations are a complex and ever-changing set of rules that differ from facility to facility. However, all of Oneida Air Systems' dust collector are NFPA Compliance Ready and we provide best practices and guidance for assisting customers - read our NFPA Reference Guide for more information.
I hear a loud bang/pop from the dust bin when I turn the system on, is this normal?
If the drum of your system is empty, you may hear a loud noise as the metal flexes from the suction pressure created when turning the system on. This sound will stop when material is within the drum and is to be expected.
What dust can be collected with your collector?
Oneida Air Systems' dust collectors are designed and tested for wood and wood dust. They can and have been used effectively for various other debris, including drywall dust, paper dust, agricultural dust, and metal chips. Please note that some common materials when cut, ground or processed by machinery may become highly toxic, flammable, or deflagrable and explosive. Customers must ensure that their particular use of a dust collection system is in accordance with national, state, local, NFPA, OSHA and all other applicable codes.
What is a static dissipative material?
This term refers to the range of conductivity that a material has. Static dissipative materials range from 106-1012 Ohms. More information about static resistance can be found here.
How do I troubleshoot an air leak with my cyclone?
Even a small leak can significantly affect the overall separation performance of the cyclone. If you can't audibly pinpoint where the leak might be coming from, one of the simplest ways to check for air leaks is with a smoke test. Click "Read More" for further instructions and tips.
What are the dimensions for this product?
General system dimensions are shown in the Specifications tab on each product page. More detailed information can be found in the product's Owner's Manual, located under the Documents tab.
Is it normal for my dust collector to run hot?
Yes. All motors generate heat, which is why it is essential to have proper ventilation around the motor for cooling.
Why does the bin level indicator flash when the bin is empty?
Because the Dust Sentry works via an adjustable infrared sensor, it can sometimes show false positives with an empty container because of the reflective surface at the bottom of the steel drum. This issue will go away soon after the system is used; once the bottom of the drum has sawdust on it, the Dust Sentry should no longer give a false positive. It can also be resolved by painting/coloring the inside bottom of the drum so that it is no longer reflective enough to affect the sensor.
How do I adjust the bin level sensor?
Adjust the detection of the dust level of the infrared sensor by rotating the Level Set Screw. Turning it towards the plus sign (+) will lengthen the range of the sensor; turning it towards the minus sign (-) will shorten the sensor’s range. DO NOT force the level set screw.
What's the recommended range I should set the bin level sensor at?
We recommend that the sensor be set to alert at a distance of 4-6". To test the range, place your hand in front of the sensor, while the Dust Sentry is plugged in, to represent the dust drum filling up.
Should the inlet reducer for my dust collector be crimped or straight?
The inlets on all of our dust collectors are sized to fit standard ductwork. If you need a reducer to connect to ductwork that’s smaller than your collector’s inlet, the end of the reducer that connects to the inlet will need to be crimped, so that it will fit inside the inlet.
Can Dust Sentry Panel be mounted outside in weather?
No, there is electrical components inside and if it got wet there is a potential it would short circuit.
Can I lengthen the Bin Level Sensor power cord?
The 8' power cord can be extended to any length using wire of the same gauge or higher.
Did you find what you were looking for?
Frequently Bought Together
Total price
What's this? Check "Remember Me" to access your shopping cart on this computer even if you are not signed in.